Micron Document
<!DOCTYPE html>
<html class="client-nojs vector-feature-language-in-header-enabled vector-feature-language-in-main-page-header-disabled vector-feature-page-tools-pinned-disabled vector-feature-toc-pinned-clientpref-0 vector-toc-not-available vector-feature-main-menu-pinned-disabled vector-feature-limited-width-clientpref-1 vector-feature-limited-width-content-enabled vector-feature-custom-font-size-clientpref-1 vector-feature-appearance-pinned-clientpref-0 skin-theme-clientpref-day vector-sticky-header-enabled" lang="de" dir="ltr"><head>
<meta charset="UTF-8">
<title>VM-Aware Storage</title>
<meta name="viewport" content="width=device-width, initial-scale=1.0">
<link rel="icon" type="image/png" href="./_res_/favicon.png">
<link rel="canonical" href="https://de.wikipedia.org/wiki/VM-Aware_Storage"> <link href="./_mw_/ext.cite.styles.css" rel="stylesheet" type="text/css">
<link href="./_mw_/ext.wikimediamessages.styles.css" rel="stylesheet" type="text/css">
<link href="./_mw_/skins.vector.icons.css" rel="stylesheet" type="text/css">
<link href="./_mw_/skins.vector.search.codex.styles.css" rel="stylesheet" type="text/css">
<link href="./_mw_/skins.vector.styles.css" rel="stylesheet" type="text/css">
<meta name="ResourceLoaderDynamicStyles" content="">
<link href="./_mw_/ext.gadget.citeRef.css" rel="stylesheet" type="text/css">
<link href="./_mw_/ext.gadget.defaultPlainlinks.css" rel="stylesheet" type="text/css">
<link href="./_mw_/ext.gadget.dewikiCommonHide.css" rel="stylesheet" type="text/css">
<link href="./_mw_/ext.gadget.dewikiCommonLayout.css" rel="stylesheet" type="text/css">
<link href="./_mw_/ext.gadget.dewikiCommonStyle.css" rel="stylesheet" type="text/css">
<link href="./_mw_/ext.gadget.dewikiDarkmode.css" rel="stylesheet" type="text/css">
<link href="./_mw_/ext.gadget.dewikiResponsive.css" rel="stylesheet" type="text/css">
<link href="./_mw_/ext.gadget.specialSearch.css" rel="stylesheet" type="text/css">
<link rel="stylesheet" type="text/css" href="./_mw_/site.styles.css">
<link rel="stylesheet" type="text/css" href="./_mw_/noscript.css">
<link rel="stylesheet" type="text/css" href="./_res_/footer.css">
<link rel="stylesheet" type="text/css" href="./_res_/vector-2022.css">
</head>
<body class="skin--responsive skin-vector skin-vector-search-vue mediawiki ltr sitedir-ltr mw-hide-empty-elt ns-0 ns-subject page-VM-Aware_Storage rootpage-VM-Aware_Storage skin-vector-2022 action-view">
<div class="mw-page-container">
<div class="mw-page-container-inner">
<div class="mw-content-container">
<main id="content" class="mw-body">
<header class="mw-body-header vector-page-titlebar">
<h1 id="firstHeading" class="firstHeading mw-first-heading"><span class="mw-page-title-main">VM-Aware Storage</span></h1>
</header>
<a id="top"></a>
<div id="bodyContent" class="vector-body ve-init-mw-desktopArticleTarget-targetContainer" aria-labelledby="firstHeading" data-mw-ve-target-container="">
<div id="contentSub">
<div id="mw-content-subtitle"></div>
</div>
<div id="mw-content-text" class="mw-body-content mw-content-ltr" lang="de" dir="ltr"><div class="mw-content-ltr mw-parser-output" lang="de" dir="ltr"><p><b>VM-Aware Storage</b> (<b>VAS</b>) ist ein <a href="Datenspeicher" title="Datenspeicher">Datenspeicher</a>, der speziell entworfen wurde, um Speicher für <a href="Virtuelle_Maschine" title="Virtuelle Maschine">virtuelle Maschinen</a> (VMs) in einem <a href="Rechenzentrum" title="Rechenzentrum">Rechenzentrum</a> zu verwalten. Das Ziel ist es, Speicher anzubieten, der, verglichen mit Universalspeicher, einfacher zu verwenden und auf das Zusammenwirken mit VMs optimiert ist. VM-Aware Storage ermöglicht es, Speicher als integralen Teil einer VM zu verwalten, anstatt als <a href="Logical_Unit_Number" title="Logical Unit Number">Logical Unit Number</a> (LUN) oder <a href="Partition_(Datentr%C3%A4ger)" title="Partition (Datenträger)">Volumen</a>, das separat konfiguriert und verwaltet wird.
</p><p>VM-Aware Storage wird häufig in Verbindung mit anderen VM-aware-Komponenten und -Prozessen verwendet, wie VM-Aware-<a href="Rechnernetz" title="Rechnernetz">Netzwerken</a>, VM-Aware-<a href="Datensicherung" title="Datensicherung">Datensicherungen</a> und VM-Aware-<a href="Antivirenprogramm" title="Antivirenprogramm">Virensuche</a>.<sup id="cite_ref-zhu07_1-0" class="reference"><a href="#cite_note-zhu07-1"><span class="cite-bracket">[</span>1<span class="cite-bracket">]</span></a></sup> VM-Aware Storage hat einige Gemeinsamkeiten mit <a href="Software-defined_Networking" title="Software-defined Networking">Software-defined Networking</a> und kann davon profitieren, unterscheidet sich aber von Letzterem darin, dass SDN physische Technik bereitstellt, die über Software angepasst und eingerichtet werden kann, wohingegen VM-Aware Storage für virtuelle Maschinen entworfen wurde.<sup id="cite_ref-greene09_2-0" class="reference"><a href="#cite_note-greene09-2"><span class="cite-bracket">[</span>2<span class="cite-bracket">]</span></a></sup><sup id="cite_ref-herrod12_3-0" class="reference"><a href="#cite_note-herrod12-3"><span class="cite-bracket">[</span>3<span class="cite-bracket">]</span></a></sup>
</p>

<div class="mw-heading mw-heading2"><h2 id="Hintergrund">Hintergrund</h2></div>
<p>Der Einsatz von <a href="Server" title="Server">Server</a>-<a href="Virtualisierung_(Informatik)" title="Virtualisierung (Informatik)">Virtualisierung</a> ist seit Veröffentlichung des <a href="Hypervisor" title="Hypervisor">Hypervisors</a> VMware ESX im Jahr 2001 stark gestiegen. Die <a href="International_Data_Corporation" title="International Data Corporation">International Data Corporation</a> (IDC) schätzt, dass seit 2009 mehr virtuelle als physische Maschinen aufgesetzt wurden.<sup id="cite_ref-bailey09_4-0" class="reference"><a href="#cite_note-bailey09-4"><span class="cite-bracket">[</span>4<span class="cite-bracket">]</span></a></sup>
</p><p>Die Möglichkeit, Anwendungen, die auf zig Servern verteilt laufen, auf einer physischen Maschine mit einem Hypervisor zu vereinen, hat zu enormen Kosteneinsparungen sowohl bei Geräten als auch durch automatisierte Verwaltung der virtuellen Server geführt. Durch diese Vorteile haben seit 2010 viele Unternehmen die Richtlinie „Virtualisierung zuerst“ umgesetzt, die aussagt, dass alle neuen Servereinrichtungen virtuell geschehen sollen, es sei denn, bestimmte Gründe sprächen dagegen und für den Einsatz eines physischen Servers.<sup id="cite_ref-burt10_5-0" class="reference"><a href="#cite_note-burt10-5"><span class="cite-bracket">[</span>5<span class="cite-bracket">]</span></a></sup>
</p><p>Da durch Virtualisierung die Kosten von Serverhardware gesenkt werden konnten, wurde die Speichersysteme zum dominierenden Faktor für die Kosten und Komplexität virtueller Infrastrukturen. In fast allen Verwaltungswerkzeugen für virtuelle Systeme der frühen 2000er Jahre wurden Rechnerressourcen, wie CPU und Hauptspeicher, separat von Speicherressourcen konfiguriert und verwaltet. Serverressourcen wurden häufig von einem anderen Team verwaltet als die Speicherinfrastruktur. Die Server und Speichersysteme separat zu konfigurieren und sie zur Zusammenarbeit zu bewegen, erforderte häufig abgestimmte, umfangreiche Planung, Integration und Fehlerbehebung.
</p>
<div class="mw-heading mw-heading2"><h2 id="Entstehung">Entstehung</h2></div>
<p>Um die Verwaltbarkeit von Speicher zu erhöhen, gingen Speichersystemanbieter dazu über, ihre Lösungen mit den umgebenden virtuellen Komponenten (häufig virtuelle Infrastruktur genannt) kompatibler zu gestalten. Anfängliche Verbesserungen bestanden aus <a href="Skriptsprache" title="Skriptsprache">Skripten</a> und <a href="Plug-in" title="Plug-in">Plug-ins</a> für virtuelle Infrastrukturen, um übliche Arbeitsabläufe, wie das Zuweisen von Speicher zu VMs, unkomplizierter zu gestalten. Als Folge wurden diese Aufgaben einfacher umsetzbar.
</p><p>Um weitere Vorteile zu erzielen und virtuellen Infrastrukturen die Möglichkeit zu geben, die zugrundeliegenden Speichersystemfunktionen, wie <a href="Schnappschuss_(Informationstechnik)" title="Schnappschuss (Informationstechnik)">Schnappschüsse</a>, Klonen (beschreibbare Snapshots), <a href="Replikation_(Datenverarbeitung)" title="Replikation (Datenverarbeitung)">Replikation</a> und <a href="Quality_of_Service" title="Quality of Service">Quality of Service</a> (QoS), besser nutzen zu können, begannen Hypervisorhersteller, neue Speicher-<a href="Kommunikationsprotokoll" title="Kommunikationsprotokoll">Protokolle</a> und -Erweiterungen (VAAI,<sup id="cite_ref-vmware1_6-0" class="reference"><a href="#cite_note-vmware1-6"><span class="cite-bracket">[</span>6<span class="cite-bracket">]</span></a></sup> StorageLink<sup id="cite_ref-citrix1_7-0" class="reference"><a href="#cite_note-citrix1-7"><span class="cite-bracket">[</span>7<span class="cite-bracket">]</span></a></sup>) zu veröffentlichen und zu implementieren, um den Speicher in virtuellen Umgebungen zu verwalten.
</p><p>Diese frühen Schritte verbesserten zwar die Verwendbarkeit und Effizienz von Speichern innerhalb von virtuellen Infrastrukturen, berücksichtigten jedoch nicht die grundsätzliche Trennung zwischen virtuellen Infrastrukturen und Speichersystemen. Da virtuelle Infrastrukturen entworfen wurden, um VMs zu verwalten, Speichersysteme hingegen entworfen wurden, um LUNs und Partitionen zu verwalten, die keine direkte Beziehung zu VMs haben.
</p><p>Unabhängig von VMware, begannen auch verschiedene <a href="Start-up-Unternehmen" title="Start-up-Unternehmen">Startups</a>, VM-aware-Storage-Produkte unter der Verwendung vorhandener Oberflächen für virtuelle Infrastrukturverwaltung anzubieten. Diese Lösungen wurden entworfen, um dieselben VM-Abstraktionen zu unterstützen, und ermöglichen Speicherverwaltung in der Feinheit auf VM-Ebene.
</p>
<div class="mw-heading mw-heading2"><h2 id="Vergleich_mit_Universalspeicher">Vergleich mit Universalspeicher</h2></div>
<p>Universalspeichersysteme wurden in Hinblick auf Speicherprotokolle, wie <a href="Small_Computer_System_Interface" title="Small Computer System Interface">SCSI</a>, <a href="ISCSI" title="ISCSI">iSCSI</a>, <a href="Network_File_System" title="Network File System">Network File System</a> (NFS) und <a href="Server_Message_Block" title="Server Message Block">Server Message Block</a> (SMB), entwickelt, die es lange gab, bevor Virtualisierung aufkam. Als Ergebnis sind ihre grundlegenden Verwaltungseinheiten LUNs und Volumen, die wenig mit VMs zu tun haben. Universalspeichersysteme werden überwiegend unabhängig von der virtuellen Infrastruktur konfiguriert und verwaltet. Die Abstraktionen der VM werden von Administratoren auf die Speichersysteme abgebildet. Sie müssen dann diese Zuordnungen verwalten und Richtlinien sowie Prozesse für das Übersetzen von Operationen auf VMs in die entsprechenden Operationen für LUNs und Partitionen erstellen.<sup id="cite_ref-foskett12a_8-0" class="reference"><a href="#cite_note-foskett12a-8"><span class="cite-bracket">[</span>8<span class="cite-bracket">]</span></a></sup>
</p><p>Da es zum Beispiel keine Standardprotokolle zum Erstellen und Löschen von LUNs und Volumen gibt, speichern die meisten virtuellen Infrastrukturen viele VMs in einem einzelnen LUN oder Volumen, um Bereitstellungs- und Verwaltungsaufwand auszugleichen. Da allgemeine Speichersysteme die meisten Speicherverwaltungsfunktionen, wie Überwachung, Schnappschüsse, Klonen, Replikation und QoS, für LUNs und Volumen anstatt für VMs und virtuelle Festplatten umsetzen, bedeutet dies, dass Speichersysteme die Fähigkeit verlieren, diese Vorgänge auf einzelnen VMs auszuführen.<sup id="cite_ref-foskett12c_9-0" class="reference"><a href="#cite_note-foskett12c-9"><span class="cite-bracket">[</span>9<span class="cite-bracket">]</span></a></sup>
</p>
<div class="mw-heading mw-heading2"><h2 id="Einzelnachweise">Einzelnachweise</h2></div>
<ol class="references">
<li id="cite_note-zhu07-1"><span class="mw-cite-backlink"><a href="#cite_ref-zhu07_1-0">↑</a></span> <span class="reference-text">
David Y. Zhu, Erika Chin: <a rel="nofollow" class="external text" href="https://web.archive.org/web/20120907025916/http://radlab.cs.berkeley.edu/w/upload/3/3d/Detecting_VM_Aware_Malware.pdf"><cite>Detection of VM-Aware Malware</cite></a> (<span class="webarchiv-memento"><a href="Webarchivierung#Begrifflichkeiten" title="Webarchivierung">Memento</a></span> des <style data-mw-deduplicate="TemplateStyles:r250917974">
/* start https://de.wikipedia.org/ */


.mw-parser-output .dewiki-iconexternal>a{background-position:center right!important;background-repeat:no-repeat!important}body.skin-minerva .mw-parser-output .dewiki-iconexternal>a{background-image:url("./_mw_/OOjs_UI_icon_external-link-ltr-progressive.svg")!important;background-size:10px!important;padding-right:13px!important}body.skin-timeless .mw-parser-output .dewiki-iconexternal>a,body.skin-monobook .mw-parser-output .dewiki-iconexternal>a{background-image:url("./_mw_/MediaWiki_external_link_icon.svg")!important;padding-right:13px!important}body.skin-vector .mw-parser-output .dewiki-iconexternal>a{background-image:url("./_mw_/Link.ernal-small-ltr-progressive.svg")!important;background-size:0.857em!important;padding-right:1em!important}


/* end https://de.wikipedia.org/ */
</style><span class="dewiki-iconexternal"><a class="external text" href="https://redirecter.toolforge.org/?url=http%3A%2F%2Fradlab.cs.berkeley.edu%2Fw%2Fupload%2F3%2F3d%2FDetecting_VM_Aware_Malware.pdf">Originals</a></span> vom 7.&nbsp;September 2012 im <i><a href="Internet_Archive" title="Internet Archive">Internet Archive</a></i>) In: <cite>Technical report</cite>, UC Berkeley, Dezember 2007. Abgerufen am 25.&nbsp;Juni 2012 <small class="archiv-bot"><span class="wp_boppel noviewer" aria-hidden="true" role="presentation"><span typeof="mw:File"><span title="i"></span></span></span>&nbsp;<b>Info:</b> Der Archivlink wurde automatisch eingesetzt und noch nicht geprüft. Bitte prüfe Original- und Archivlink gemäß Anleitung und entferne dann diesen Hinweis.</small><span style="display:none"><a rel="nofollow" class="external text" href="http://IABotmemento.invalid/http://radlab.cs.berkeley.edu/w/upload/3/3d/Detecting_VM_Aware_Malware.pdf">@1</a></span><span style="display:none"><a rel="nofollow" class="external text" href="http://radlab.cs.berkeley.edu/w/upload/3/3d/Detecting_VM_Aware_Malware.pdf">@2</a></span><span style="display:none">Vorlage:Webachiv/IABot/radlab.cs.berkeley.edu</span><span class="Z3988" title="ctx_ver=Z39.88-2004&amp;rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Adc&amp;rft.type=newspaperArticle&amp;rft.subject=News&amp;rft.au=David+Y.+Zhu%2C+Erika+Chin&amp;rft.title=Detection+of+VM-Aware+Malware&amp;rft.identifier=http%3A%2F%2Fradlab.cs.berkeley.edu%2Fw%2Fupload%2F3%2F3d%2FDetecting_VM_Aware_Malware.pdf&amp;rft.source=Technical+report&amp;rft.publisher=UC+Berkeley&amp;rft.date=2007-12">&nbsp;</span></span>
</li>
<li id="cite_note-greene09-2"><span class="mw-cite-backlink"><a href="#cite_ref-greene09_2-0">↑</a></span> <span class="reference-text">Kate Greene: <a rel="nofollow" class="external text" href="http://www.technologyreview.com/biotech/22120/"><cite>TR10: Software-Defined Networking</cite></a> In: <cite>Technology Review</cite>, MIT, March–April 2009. Abgerufen am 25.&nbsp;Juni 2012<span class="Z3988" title="ctx_ver=Z39.88-2004&amp;rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Adc&amp;rft.type=newspaperArticle&amp;rft.subject=News&amp;rft.au=Kate+Greene&amp;rft.title=TR10%3A+Software-Defined+Networking&amp;rft.identifier=http%3A%2F%2Fwww.technologyreview.com%2Fbiotech%2F22120%2F&amp;rft.source=Technology+Review&amp;rft.publisher=MIT&amp;rft.date=March%E2%80%93April+2009">&nbsp;</span></span>
</li>
<li id="cite_note-herrod12-3"><span class="mw-cite-backlink"><a href="#cite_ref-herrod12_3-0">↑</a></span> <span class="reference-text">Steven Herrod: <a rel="nofollow" class="external text" href="http://cto.vmware.com/interop-and-the-software-defined-datacenter/"><cite>Interop and the Software-Defined Datacenter</cite></a> In: <cite>cto.vmware.com</cite>, VMware, Mai 2012. Abgerufen am 25.&nbsp;Juni 2012<span class="Z3988" title="ctx_ver=Z39.88-2004&amp;rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Adc&amp;rft.type=newspaperArticle&amp;rft.subject=News&amp;rft.au=Steven+Herrod&amp;rft.title=Interop+and+the+Software-Defined+Datacenter&amp;rft.identifier=http%3A%2F%2Fcto.vmware.com%2Finterop-and-the-software-defined-datacenter%2F&amp;rft.source=cto.vmware.com&amp;rft.publisher=VMware&amp;rft.date=2012-05">&nbsp;</span></span>
</li>
<li id="cite_note-bailey09-4"><span class="mw-cite-backlink"><a href="#cite_ref-bailey09_4-0">↑</a></span> <span class="reference-text">
Michelle Bailey: <a rel="nofollow" class="external text" href="https://web.archive.org/web/20120510061748/https://www.vmware.com/files/pdf/Virtualization-application-based-cost-model-WP-EN.pdf"><cite>The Economics of Virtualization: Moving Toward an Application-Based Cost Model</cite></a> (<span class="webarchiv-memento"><a href="Webarchivierung#Begrifflichkeiten" title="Webarchivierung">Memento</a></span> des <span class="dewiki-iconexternal"><a class="external text" href="https://redirecter.toolforge.org/?url=http%3A%2F%2Fwww.vmware.com%2Ffiles%2Fpdf%2FVirtualization-application-based-cost-model-WP-EN.pdf">Originals</a></span> vom 10.&nbsp;Mai 2012 im <i><a href="Internet_Archive" title="Internet Archive">Internet Archive</a></i>) In: <cite>Research sponsored by VMware</cite>, International Data Corporation, November 2009. Abgerufen am 25.&nbsp;Juni 2012 <small class="archiv-bot"><span class="wp_boppel noviewer" aria-hidden="true" role="presentation"><span typeof="mw:File"><span title="i"></span></span></span>&nbsp;<b>Info:</b> Der Archivlink wurde automatisch eingesetzt und noch nicht geprüft. Bitte prüfe Original- und Archivlink gemäß Anleitung und entferne dann diesen Hinweis.</small><span style="display:none"><a rel="nofollow" class="external text" href="http://IABotmemento.invalid/http://www.vmware.com/files/pdf/Virtualization-application-based-cost-model-WP-EN.pdf">@1</a></span><span style="display:none"><a rel="nofollow" class="external text" href="http://www.vmware.com/files/pdf/Virtualization-application-based-cost-model-WP-EN.pdf">@2</a></span><span style="display:none">Vorlage:Webachiv/IABot/www.vmware.com</span><span class="Z3988" title="ctx_ver=Z39.88-2004&amp;rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Adc&amp;rft.type=newspaperArticle&amp;rft.subject=News&amp;rft.au=Michelle+Bailey&amp;rft.title=The+Economics+of+Virtualization%3A+Moving+Toward+an+Application-Based+Cost+Model&amp;rft.identifier=http%3A%2F%2Fwww.vmware.com%2Ffiles%2Fpdf%2FVirtualization-application-based-cost-model-WP-EN.pdf&amp;rft.source=Research+sponsored+by+VMware&amp;rft.publisher=International+Data+Corporation&amp;rft.date=2009-11">&nbsp;</span></span>
</li>
<li id="cite_note-burt10-5"><span class="mw-cite-backlink"><a href="#cite_ref-burt10_5-0">↑</a></span> <span class="reference-text">Jeffrey Burt: <a rel="nofollow" class="external text" href="http://www.eweek.com/c/a/IT-Infrastructure/Enterprises-Thinking-Virtualization-First-IDC-Says-896006/"><cite>Enterprises Thinking Virtualization First</cite></a> In: <cite>eWeek.com</cite>, International Data Corporation, April 2010. Abgerufen am 25.&nbsp;Juni 2012<span class="Z3988" title="ctx_ver=Z39.88-2004&amp;rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Adc&amp;rft.type=newspaperArticle&amp;rft.subject=News&amp;rft.au=Jeffrey+Burt&amp;rft.title=Enterprises+Thinking+Virtualization+First&amp;rft.identifier=http%3A%2F%2Fwww.eweek.com%2Fc%2Fa%2FIT-Infrastructure%2FEnterprises-Thinking-Virtualization-First-IDC-Says-896006%2F&amp;rft.source=eWeek.com&amp;rft.publisher=International+Data+Corporation&amp;rft.date=2010-04">&nbsp;</span></span>
</li>
<li id="cite_note-vmware1-6"><span class="mw-cite-backlink"><a href="#cite_ref-vmware1_6-0">↑</a></span> <span class="reference-text">VMware Knowledge Base: <a rel="nofollow" class="external text" href="http://kb.vmware.com/selfservice/microsites/search.do?language=en_US&amp;cmd=displayKC&amp;externalId=1021976"><cite>vStorage APIs for Array Integration FAQ</cite></a>, VMware. Abgerufen am 25.&nbsp;Juni 2012<span class="Z3988" title="ctx_ver=Z39.88-2004&amp;rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Adc&amp;rft.type=newspaperArticle&amp;rft.subject=News&amp;rft.au=VMware+Knowledge+Base&amp;rft.title=vStorage+APIs+for+Array+Integration+FAQ&amp;rft.identifier=http%3A%2F%2Fkb.vmware.com%2Fselfservice%2Fmicrosites%2Fsearch.do%3Flanguage%3Den_US%26cmd%3DdisplayKC%26externalId%3D1021976&amp;rft.publisher=VMware">&nbsp;</span></span>
</li>
<li id="cite_note-citrix1-7"><span class="mw-cite-backlink"><a href="#cite_ref-citrix1_7-0">↑</a></span> <span class="reference-text">Citrix Developer Network: <a rel="nofollow" class="external text" href="http://community.citrix.com/display/xs/Citrix+StorageLink"><cite>What is StorageLink?</cite></a> In: <cite>XenServer Best Practices Citrix StorageLink</cite>, Citrix. Abgerufen am 25.&nbsp;Juni 2012<span class="Z3988" title="ctx_ver=Z39.88-2004&amp;rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Adc&amp;rft.type=newspaperArticle&amp;rft.subject=News&amp;rft.au=Citrix+Developer+Network&amp;rft.title=What+is+StorageLink%3F&amp;rft.identifier=http%3A%2F%2Fcommunity.citrix.com%2Fdisplay%2Fxs%2FCitrix%2BStorageLink&amp;rft.source=XenServer+Best+Practices+Citrix+StorageLink&amp;rft.publisher=Citrix">&nbsp;</span></span>
</li>
<li id="cite_note-foskett12a-8"><span class="mw-cite-backlink"><a href="#cite_ref-foskett12a_8-0">↑</a></span> <span class="reference-text">Stephen Foskett: <a rel="nofollow" class="external text" href="http://blog.fosketts.net/2012/05/23/io-blender-part-1-ye-olde-storage-io-path/"><cite>The I/O Blender Part 1: Ye Olde Storage I/O Path</cite></a>, blog.fosketts.net, Mai 2012. Abgerufen am 27.&nbsp;Juni 2012<span class="Z3988" title="ctx_ver=Z39.88-2004&amp;rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Adc&amp;rft.type=newspaperArticle&amp;rft.subject=News&amp;rft.au=Stephen+Foskett&amp;rft.title=The+I%2FO+Blender+Part+1%3A+Ye+Olde+Storage+I%2FO+Path&amp;rft.identifier=http%3A%2F%2Fblog.fosketts.net%2F2012%2F05%2F23%2Fio-blender-part-1-ye-olde-storage-io-path%2F&amp;rft.publisher=blog.fosketts.net&amp;rft.date=2012-05">&nbsp;</span></span>
</li>
<li id="cite_note-foskett12c-9"><span class="mw-cite-backlink"><a href="#cite_ref-foskett12c_9-0">↑</a></span> <span class="reference-text">Stephen Foskett: <a rel="nofollow" class="external text" href="http://blog.fosketts.net/2012/05/25/io-blender-part-3-behold-power-demultiplexer/"><cite>The I/O Blender Part 3: Behold the Power of the Demultiplexer</cite></a>, blog.fosketts.net, Mai 2012. Abgerufen am 27.&nbsp;Juni 2012<span class="Z3988" title="ctx_ver=Z39.88-2004&amp;rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Adc&amp;rft.type=newspaperArticle&amp;rft.subject=News&amp;rft.au=Stephen+Foskett&amp;rft.title=The+I%2FO+Blender+Part+3%3A+Behold+the+Power+of+the+Demultiplexer&amp;rft.identifier=http%3A%2F%2Fblog.fosketts.net%2F2012%2F05%2F25%2Fio-blender-part-3-behold-power-demultiplexer%2F&amp;rft.publisher=blog.fosketts.net&amp;rft.date=2012-05">&nbsp;</span></span>
</li>
</ol></div><!--htdig_noindex--><div><div class="zim-footer">
Dieser Artikel wurde von <a class="external text" title="Zuletzt bearbeitet am 2023-09-16" href="https://de.wikipedia.org/wiki/?title=VM-Aware_Storage&amp;oldid=237382214">Wikipedia</a> herausgegeben. Der Text ist unter <a class="external text" href="https://creativecommons.org/licenses/by-sa/4.0/deed.de">Creative Commons Attribution-Share Alike 4.0</a> verfügbar, sofern nicht anders angegeben. Für die Mediendateien können zusätzliche Bedingungen gelten.